CG Emotron VSR Series Solar Pump Drives: Complete Guide to Features, Specifications & Programming

CG Emotron VSR Series Solar Pump Drives: Complete Guide to Features, Specifications & Programming

⚡ The VSR series from CG Emotron (CG Drives & Automation) is a dedicated solar pumping drive built for dependable, economical, user-friendly performance on borewell, irrigation and water-supply pumps. A soft-start feature prevents water hammering and extends system life, while a self-adaptive, high-accuracy built-in MPPT algorithm dynamically tracks the solar array’s maximum power point for the best possible water flow output. VSR drives accept both DC solar-array input and AC grid/generator input, so a pump keeps running even when the sun doesn’t cooperate. This guide covers everything from decoding the model number to wiring the drive and getting it running from the keypad.


💡 Main Features

✅ Supports over-current, over-voltage, phase loss, short-circuit and over-temperature protection
✅ Self-adaptive, high-accuracy MPPT (Maximum Power Point Tracking) algorithm, enhancing daily water delivery and productivity
✅ Solar power tracking efficiency of up to 99%
✅ Specialised features for water pumping applications, including tank-level control
✅ Operates seamlessly on both DC solar-panel and AC grid power sources
✅ Built-in dry-run protection, safeguarding the pump from damage and reducing maintenance costs and downtime
✅ Automatically enters dormancy mode and wakes again according to sunlight intensity
✅ Compatible with any remote monitoring system via Modbus RTU protocol
✅ Capable of driving both induction motors and permanent-magnet synchronous motors


📋 Understanding the VSR Model Number

Every VSR drive’s nameplate encodes its specification in the model number. Here’s how VSR48-003-20CEB breaks down:

Code PositionMeaning
VSRProduct series — VSR = Solar drive
48 / 23 / 11Input AC voltage level — 48 = 380–480V AC/540V DC · 23 = 220–240V AC/310V DC · 11 = 110–130V AC/160V DC
003 … 210Rated current code (A) — from 003 (2.5A) up to 210 (210A)
20Protection class — IP20
CControl panel — C = Standard panel
N / EEMC filter — N = No filter, E = EMC filter fitted
B / –Brake chopper — B = Brake chopper fitted, – = without

💡 A ‘-XS’ suffix on the model number denotes a drive with a 7-segment LCD display. The VSR line also includes an economical VSRE48 sub-series and a 310V-DC-input VSR23-XXX-D variant — both covered in the ratings table below.


⚖️ Available Models & Ratings

Model No.Recommended Solar Array (kWp)Max. Input DC Current (A)Output Current (A)Motor (kW / HP)
VSR48 series (380–480V AC / 540V DC)
VSR48-003-20CEB1.14.52.50.75 kW / 1 HP
VSR48-004-20CEB2.257.54.21.5 kW / 2 HP
VSR48-006-20CEB3.3105.52.2 kW / 3 HP
VSR48-009-20CEB6189.53.7–4 kW / 5 HP
VSR48-013-20CEB8.2520135.5 kW / 7.5 HP
VSR48-017-20CEB1130177.5 kW / 10 HP
VSR48-024-20CEB16.531.72511 kW / 15 HP
VSR48-032-20CEB22.542.23215 kW / 20 HP
VSR48-038-20CEB27.552.83718.5 kW / 25 HP
VSR48-045-20CEB3363.44522 kW / 30 HP
VSR48-060-20CEB4595.06030 kW / 40 HP
VSR48-075-20CEB55.5116.27537 kW / 50 HP
VSR48-091-20CE–67.5137.39145 kW / 60 HP
VSR48-112-20CE–82.5169.011255 kW / 70 HP
Larger ratings available on request
VSRE48 series — economical, 380–480V AC
VSRE48-003-20CEB1.14.52.50.75 kW / 1 HP
VSRE48-004-20CEB2.257.54.21.5 kW / 2 HP
VSRE48-006-20CEB3.3105.52.2 kW / 3 HP
VSRE48-009-20CEB6189.53.7–4 kW / 5 HP
VSR23 series — single-phase 220–240V AC
VSR23-2p5-20CEB0.64.52.50.37–0.4 kW / 0.5 HP
VSR23-4p2-20CEB1.17.54.20.75 kW / 1 HP
VSR23-7p5-20CEB2.25107.51.5 kW / 2 HP
VSR23-9p5-20CEB3.3189.52.2 kW / 3 HP
VSR23-XXX-D series — economical, 310V DC input only
VSR23-9p5-D3.3189.52.2 kW / 3 HP
VSR11 series — single-phase 110–130V AC
VSR11-9p5-20CEB1.6189.51.1 kW / 1.5 HP

💡 VSR48-091 and VSR48-112 ship without a brake chopper (catalog code ends “20CN–” for these two ratings) — the EMC-filter digit is still corrected to E here. VSR23-9p5-D is an economical, DC-input-only version of the VSR23-9p5 for pure solar (no AC grid backup) installations.


🔧 General Specifications

ParameterVSR48 / VSRE48VSR23VSR23-XXX-DVSR11
Maximum PV input DC voltage800V DC450V DC450V DC450V DC
Recommended Voc range500–700V DC320–370V DC360–430V DC150–430V DC
Recommended MPPT voltage range450–600V DC250–350V DC250–350V DC130–350V DC
Starting voltage range230–800V DC60–450V DC60–450V DC60–450V DC
Grid / backup generator input3-phase 415V (−20%~+20%)Single-phase 220V (−20%~+20%)— (solar only)Single-phase 110V (−15%~+20%)
Rated output voltage3-Ph 415V3-Ph 220V3-Ph 220V3-Ph 110V
Output frequency0–600Hz (default 0–50Hz) across all series
Control modesV/f control · Sensor-less vector control 1 & 2
Speed range1:50 (V/f) · 1:100 (SVC1) · 1:200 (SVC2)
Speed accuracy±0.5% (V/f) · ±0.2% (SVC1 & 2)
Torque response< 10ms (SVC1 & 2)
Overload capability150% for 60s · 180% for 10s · 200% for 1s
Built-in protectionLightning protection, over-current, over-voltage, output phase loss, under-load, under-voltage, short-circuit, overheating, water-pump dry run
Ambient temperature−10°C ~ 50°C
Altitude0–2000m (derate 1% per 100m above 1000m)
Relative humidity5%–95%, no condensation
Efficiency≥ 93% at rated power
Installation / CoolingWall or rail mounting · forced air cooling · IP20

🔌 Wiring the VSR Drive

Every VSR drive accepts a DC solar-array input at (−)/(+), with an optional AC grid/generator input for backup pumping on cloudy days or at night (except the DC-only VSR23-9p5-D). Layouts scale with power: 0.75–2.2kW models have a leaner I/O set (4 digital inputs, 2 analog inputs, 1 open-collector output), while 4–55kW VSR48 models add two more digital inputs, a second relay/open-collector output, and a third (bipolar) analog input.

Main power & motor circuit

✅ (−), (+) — DC input from the solar array
✅ L1, L2, L3 (VSR48) / L, N (VSR23, VSR11) — AC grid or backup-generator input, through an MCCB
✅ PB — external braking resistor connection
✅ U, V, W — output to the motor
✅ Earth (⎓) — motor and drive frame earthing

Control terminals

TerminalTypeFunction
DI1–DI4 (DI1–DI6 on 4–55kW)Digital inputProgrammable switch inputs — run/stop, direction, tank-level float switches, preset speeds, etc.
DI7/HIDigital / pulse inputHigh-speed pulse input for flow/speed feedback
AI1, AI2 (+ AI3 on 4–55kW)Analog inputDC 0–10V or 0–20mA reference — e.g. a pressure transducer for constant-pressure pumping. AI3 (4–55kW) is bipolar −10V~+10V
AO1 (+ AO2 on 4–55kW)Analog output0–10V output, e.g. to a remote flow/frequency meter
Y1 / Y2/HODigital outputOpen-collector output(s), 0–24V; on 4–55kW, Y2/HO doubles as a high-speed pulse output
R1A/R1B/R1C (+ R2A/R2B/R2C on 4–55kW)Relay outputChangeover relay contact(s), 250V AC/3A or 30V DC/1A — fault indicator, contactor or pump-start signal
485+, 485−RS485Modbus RTU communication — for remote monitoring/SCADA integration
+24V, +10V, GND, PE, PLCPower/referenceOnboard supply rails for external switches and the analog reference potentiometer

⚠️ Always wire and check connections with the drive fully powered down and the DC bus capacitors discharged. Route control wiring separately from the motor power cable to avoid electrical noise affecting the analog signals.


☀️ Recommended Solar Array Configuration

The number of panels needed per string depends on each panel’s open-circuit voltage (Voc). As a guide, for a 550W panel (Voc ≈ 50V):

ModelConfiguration (panels per string × strings)
VSR23-2p5 / 4p2 / 7p5 / 9p58 × 1
VSR48-003 / 004 / 006 / 00913 × 1
VSR48-01313 × 1
VSR48-01713 × 2
VSR48-02414 × 2
VSR48-03213 × 3
VSR48-03814 × 3
VSR48-04513 × 4
VSR48-06015 × 5
VSR48-07515 × 6
VSR48-09114 × 8
VSR48-11214 × 9

💡 Configurations shift with a different panel Voc/wattage — CG’s technical team can help size the array for other panel specifications or for grid-sharing setups.


🔧 Accessories

AccessoryPart No.DescriptionConnection
Keypad – standardS-PPU-VSLCD displayRJ45
Keypad – graphicG-PPU-VSGraphical displayRJ45
Relay card*VSOPT-RLMulti-pump relay cardTerminal connection
Profibus cardVSPROFIBUS-DPProfibus communication cardDB9
Profinet card*VSPROFINET-2P2-port Profinet communication cardRJ45

*Available from ≥ 4.0kW rating.


💻 Programming & Commissioning the VSR Drive

💡 Typical first-run sequence: wire the solar array to (−)/(+) and, if fitted, the AC grid input to L1/L2/L3 (or L/N) → power up and confirm the keypad display → enter the parameter menu and set the motor nameplate data (rated voltage, current, frequency, poles) → configure the MPPT/DC-input parameters for your array’s Voc and wattage → set up any tank-level or dry-run protection inputs on the DI terminals → press RUN to confirm motor rotation direction, then let the MPPT algorithm take over as sunlight varies through the day.

Using EmoWizard software

EmoWizard helps with easy commissioning and troubleshooting of VSR series drives, offering user-friendly tools for viewing, manipulating and exchanging data with the drive. Statistics data can be plotted using the built-in oscilloscope, and the drive can be started/stopped directly from the software’s control panel.


🌍 Typical Applications

✅ Agriculture irrigation
✅ Industrial water supply
✅ Domestic water
✅ Animal husbandry
✅ Desert control
✅ Aquaculture


❓ Frequently Asked Questions

Can a VSR drive run a pump when there’s no sunlight?

✅ Yes — every VSR model except the DC-only VSR23-9p5-D accepts an AC grid or backup-generator input, so the pump can keep running from mains power when solar generation drops.

What is MPPT and why does it matter for solar pumping?

✅ Maximum Power Point Tracking continuously adjusts the drive’s operating point to extract the most power available from the solar array at any given sunlight level, cloud cover or temperature. VSR’s self-adaptive MPPT algorithm reaches up to 99% tracking efficiency, which directly translates into more water pumped per day.

Does the VSR drive protect the pump if the water source runs dry?

✅ Yes — built-in dry-run protection detects a loss of load/flow and stops the drive automatically, preventing pump damage and reducing maintenance costs.

Can the VSR drive be monitored remotely?

✅ Yes — the built-in RS485 port supports Modbus RTU, so the drive can be integrated with any compatible remote monitoring or SCADA system for irrigation or water-supply networks.


🛒 Shop the CG Emotron VSR Series

🚀 These VSR models are currently in stock and ready to ship:

✅ VSR48-009-20CEB — 3.7–4kW / 5HP
✅ VSR48-013-20CEB — 5.5kW / 7.5HP
✅ VSR48-017-20CEB — 7.5kW / 10HP
✅ VSR48-024-20CEB — 11kW / 15HP
✅ VSR48-032-20CEB — 15kW / 20HP
✅ VSR48-038-20CEB — 18.5kW / 25HP
✅ VSR48-045-20CEB — 22kW / 30HP
✅ VSR48-060-20CEB — 30kW / 40HP
✅ VSR48-075-20CEB — 37kW / 50HP
✅ VSR48-091-20CE– — 45kW / 60HP
✅ VSR48-112-20CE– — 55kW / 70HP
✅ VSRE48-009 — 3.7–4kW / 5HP (economical series)
✅ VSR23-9P5 — 2.2kW / 3HP (single-phase 230V input)

💡 Not yet listed in the shop: VSR48-003/004/006, VSRE48-003/004/006, VSR23-2p5/4p2/7p5, VSR23-9p5-D, and the VSR11-9p5. Get in touch for availability on these ratings.