CG Emotron AMX Series AC Drives: Complete Guide to Features, Specifications & Programming
⚡ The AMX Series from CG Power and Industrial Solutions (Emotron — a CG Drives and Automation product) is a compact, general-purpose AC drive built for a wide range of industrial applications, from FMCG and packaging lines to ports, cement, chemicals, textiles and renewables. It’s designed to drive both induction and permanent magnet motors, with advanced V/F and field-oriented control for precise speed regulation, fast torque response, and improved low-frequency performance. The currently confirmed AMX48 range spans 1.5kW to 18.5kW Normal Duty (0.75kW to 15kW Heavy Duty) across frames X1–X3, with a further 22kW to 55kW Normal Duty range across frames X4–X5 listed by CG as an upcoming addition. This guide covers everything from decoding the model number to wiring the drive and getting it commissioned.
💡 Main Features
✅ Power that delivers — high starting torque characteristics and reliable performance under heavy-load startup conditions
✅ Built for extreme environments — robust drive with conformal coating, engineered to withstand hot, humid and harsh operating conditions, rated for 50°C ambient without derating
✅ Cleaner, safer installations — optional Category C3 EMC/EMI filter ensures superior electromagnetic compatibility
✅ Smarter logic control — load monitoring, timers, counters and virtual I/Os enable flexible in-built logic without external hardware
✅ Intuitive operation — user-friendly GUI with advanced debug tools, robust software and streamlined parameter configuration
✅ Real-time visualization — graphical PPU with an on-panel oscilloscope for instant monitoring and waveform analysis
✅ Hassle-free updates — USB Type-C firmware upgrade, mobile/laptop compatible, fast and adapter-free
✅ Advanced braking control — built-in brake chopper (up to 45kW) and integrated vector braking for quick, safe, controlled stops
✅ Intelligent load monitoring — a standard load monitor function gives precise insight into operational demands
✅ Streamlined configuration — a detachable control panel with parameter copy function, and the ability to set parameters directly in process units (m/sec, tons/h, cycles/min)
✅ Energy efficiency — a built-in energy-saving function automatically pauses the motor when operation isn’t required
✅ Specialized application macros — pre-configured settings for brake control and multi-pump systems to simplify complex setups
✅ Wide tolerance to voltage and frequency fluctuations — keeps the drive running stably even under unstable input conditions
📋 Understanding the AMX Model Number
Every AMX drive’s part number follows the format AMX48-004-20DNB. Here’s how each position decodes:
| Code Position | Meaning |
|---|---|
| AMX | Product series — AMX = General purpose drive |
| 48 — Input AC Voltage Level | 48 = 230–480V AC / 540V DC |
| 004 — Rated Current | A code for the drive’s rated current in amps — e.g. 004 = 4.2A, 038 = 38A |
| 20 — Protection Class | 20 = IP20 |
| D — Control Panel | D = Graphical panel (LCD keypad, fitted as standard) |
| N/E — EMC Filter | N = No filter · E = With Category C3 EMC filter |
| B — Brake Chopper | B = With brake chopper · – (blank) = Without brake chopper |
💡 For example, AMX48-004-20DEB is a 4.2A-rated, 230–480VAC drive, IP20, with a graphical keypad, a built-in Category C3 EMC filter and a brake chopper fitted — the exact configuration each model is listed under in the Available Models & Ratings table below.
⚖️ Available Models & Ratings
The AMX48 range is dual-rated: Normal Duty (ND, 120% overload for 1 minute every 10 minutes) suits variable-torque loads at a higher continuous kW, while Heavy Duty (HD, 150% overload for 1 minute every 10 minutes) suits harder-starting, constant-torque loads at a lower continuous kW on the same drive. Ratings below are at 3-phase mains voltage 230–480V, rated data at 50°C ambient temperature.
| AMX Model | Max Output Current (A*) | Power ND (kW/HP) | Rated Current ND (A) | Power HD (kW/HP) | Rated Current HD (A) | Frame Size |
|---|---|---|---|---|---|---|
| AMX48-004-20DEB | 5 | 1.5 / 2 | 4.2 | 0.75 / 1 | 2.5 | X1 |
| AMX48-006-20DEB | 6.6 | 2.2 / 3 | 5.5 | 1.5 / 2 | 4.2 | X1 |
| AMX48-009-20DEB | 11 | 3.7 / 5 | 9.1 | 2.2 / 3 | 5.5 | X1 |
| AMX48-013-20DEB | 15.6 | 5.5 / 7.5 | 13 | 3.7 / 5 | 9.1 | X2 |
| AMX48-017-20DEB | 20 | 7.5 / 10 | 17 | 5.5 / 7.5 | 13 | X2 |
| AMX48-025-20DEB | 30 | 11 / 15 | 25 | 7.5 / 10 | 17 | X3 |
| AMX48-032-20DEB | 38.5 | 15 / 20 | 32 | 11 / 15 | 25 | X3 |
| AMX48-038-20DEB | 44.5 | 18.5 / 25 | 38 | 15 / 20 | 32 | X3 |
| AMX48-045-20DEB** | 54 | 22 / 30 | 45 | 18.5 / 25 | 38 | X4 |
| AMX48-060-20DEB** | 72 | 30 / 40 | 60 | 22 / 30 | 45 | X4 |
| AMX48-075-20DEB** | 90 | 37 / 50 | 75 | 30 / 40 | 60 | X5 |
| AMX48-092-20DEB** | 110.4 | 45 / 60 | 92 | 37 / 50 | 75 | X5 |
| AMX48-112-20DEB** | 134.4 | 55 / 75 | 112 | 45 / 60 | 92 | X5 |
💡 *Max output current is available for a limited time and only as long as drive temperature permits. ** The five largest models (045 through 112, frames X4–X5) are listed by CG as an “Upcoming Range” — they appear in the official catalog’s ratings table but aren’t part of the currently shipping AMX48 lineup yet. The eight confirmed models today (004 through 038, frames X1–X3) cover 1.5kW to 18.5kW Normal Duty / 0.75kW to 15kW Heavy Duty.
🔧 Technical Specifications
| Rated input voltage | 3-phase, 230V – 480V |
| Rated input frequency | 45 – 65Hz |
| Power range | 1.5 to 55kW / 2 to 75HP |
| Output voltage | 0 – Rated input voltage |
| Output frequency | 0 – 599Hz, resolution 0.01Hz |
| Control mode | V/F control, Field-oriented control (FOC) |
| Speed control range | 1:1500 closed loop vector control · 1:200 open loop vector control (minimum speed: nominal speed, 4-pole machine) |
| Speed accuracy | FOC closed loop: 0.01% of Nnom · Open loop: 0.1% of Nnom |
| Speed response | 80ms (dynamic) |
| Torque response | 5ms (dynamic) |
| Starting torque | 200% |
| Overload capability | Normal Duty: 120% for 60s · Heavy Duty: 180% for 2s, 200% for 0.5s |
| Applicable motors | Asynchronous motor, permanent magnet synchronous motor |
| IP class | IP20 |
| Input total power factor | 0.95 |
| Brake chopper | Up to 45kW: in-built · Above 45kW: optional |
| EMC filter | Category C3 (optional) |
| Switching frequency | 1.5 – 6kHz (default: 4kHz up to 45kW, 3kHz above 45kW) |
| Efficiency | 97% for models 004 to 032 · 98% for models 038 to 112 |
| Protection function | Motor I²t protection, motor lost, locked rotor, overcurrent, overvoltage, undervoltage, overtemperature, short-circuit, thermal protection of motor, motor phase loss, earth fault |
| IT-net compatible | Yes |
| Standard options | I/O board, Encoder board, PTC/PT100/PT1000 board |
| Serial communication | RS232, RS485 |
| Communication options (upcoming) | EtherNet/IP, Modbus TCP/IP, Profinet |
| CE certification | All sizes |
Environmental Conditions
| Operating environment | Indoors, no direct sunlight, free from dust, corrosive gases, flammable gases, oil mist, water vapour, water drops and salt |
| Altitude | 0 to 1000m · de-rate 1% per 100m of rated current up to 2000m |
| Storage temperature | −20°C to +60°C (−4 to +140°F) |
| Ambient temperature | −10°C to 50°C, no derating · derating 1%/°C up to 55°C |
| Relative humidity | Max 95%, no condensing and no formation of ice |
| Vibration | Per IEC 60068-2-6, sinusoidal: 10≤f≤57Hz, 0.075mm · 57<f≤150Hz, 1g |
| Contamination (IEC 60721-3-3) | No electrically conductive dust allowed; cooling air must be clean and free from corrosive materials. Chemical gases: coated boards 3C3. Solid particles: class 3S2 |
| Atmospheric pressure | 86 to 106 kPa (12.5 – 15.4 PSI) |
📏 Mechanical Specifications & Dimensions
External and installation dimensions (mm), current confirmed range only. The four smallest frames (X1–X3) share dimensions within their power group; weight and flow rate for the upcoming X4–X5 frames are not yet published by CG.
| Model No. | W | H | D | W1 | H1 | Mounting Hole | Weight (kg) | Flow Rate m³/h (ft³/min) |
|---|---|---|---|---|---|---|---|---|
| AMX48-004-20DEB | 95 | 262 | 168 | 60 | 243 | Φ5 | 1.5 | 50 (29.4) |
| AMX48-006-20DEB | 95 | 262 | 168 | 60 | 243 | Φ5 | 1.5 | 50 (29.4) |
| AMX48-009-20DEB | 95 | 262 | 168 | 60 | 243 | Φ5 | 1.5 | 50 (29.4) |
| AMX48-013-20DEB | 104 | 279 | 181 | 68 | 262 | Φ5 | 2.5 | 50 (29.4) |
| AMX48-017-20DEB | 104 | 279 | 181 | 68 | 262 | Φ5 | 2.5 | 50 (29.4) |
| AMX48-025-20DEB | 131 | 315 | 190 | 85 | 297 | Φ5 | 3.4 | 89.0 (52.4) |
| AMX48-032-20DEB | 131 | 315 | 190 | 85 | 297 | Φ5 | 3.5 | 89.0 (52.4) |
| AMX48-038-20DEB | 131 | 315 | 190 | 85 | 297 | Φ5 | 3.6 | 135 (79.4) |
| AMX48-045/060-20DEB** | 175 | 385 | 201 | 127 | 364 | Φ7 | Coming soon | Coming soon |
| AMX48-075/092/112-20DEB** | 210 | 520 | 246 | 152 | 500 | Φ7 | Coming soon | Coming soon |
🔌 Wiring & Control Terminals
The AMX48’s power stage takes 3-phase L1/L2/L3/PE mains into an optional EMC filter, then out to the motor at U/V/W. On models above 45kW without a built-in brake chopper, an external braking resistor connects across DC+/PB/DC−. All control wiring — analog and digital I/O, relay outputs and the RS485 port — lands on two removable terminal blocks (X4 and X5), with separate connectors reserved for optional fieldbus and I/O-expansion boards.
X4 terminal block (analog & digital I/O)
✅ +10VDC, AI1–AI3, GND — 3 analog inputs, 0–10V or 4–20mA
✅ AnOut1, AnOut2 — 2 analog outputs
✅ 0V, DigOut1, DigOut2 — 2 digital outputs (DigOut1 is the high-speed channel)
✅ +24VDC, DigIn1–DigIn7 — 7 digital inputs, 24VDC (DigIn7 is the high-speed channel)
✅ 485+/485− — RS485 port for Modbus communication
X5 terminal block (relay outputs)
✅ Relay 1 — R1A/R1B/R1C and Relay 2 — R2A/R2B/R2C — 2 onboard changeover relay outputs, commonly used for fault indication, contactor control or multi-pump switching logic
Control terminal summary
| Signal Type | Channels |
|---|---|
| Digital Inputs (DI) | 7 channels (DI1–DI7) — DI7 is the high-speed channel |
| Digital Outputs (DO) | 2 channels (DO1, DO2) — DO1 is the high-speed channel |
| Analog Inputs (AI) | 3 channels (AI1–AI3) |
| Analog Outputs (AO) | 2 channels (AO1, AO2) |
| Relay Outputs (RO) | 2 channels (R1, R2) |
⚠️ Always wire and check connections with the drive fully powered down and the DC bus capacitors discharged. Keep control wiring separate from the motor power cable, and fit the optional Category C3 EMC filter and a correctly sized, shielded motor cable if you need to meet EMC compliance for your installation.
💻 Programming & Commissioning the AMX Drive
The AMX ships with a graphical LCD keypad as standard, and can be configured either from the keypad directly or from a PC via CG’s own EmoSoftCom software.
Keypad & PC tools
✅ Graphical LCD keypad (standard) — multi-row, high-resolution display showing motor speed, current, voltage and frequency in real time, plus data trends and waveforms; supports parameter backup/download, customizable display screens, detailed fault descriptions and alarm indicators, and forward/reverse control from the keypad itself
✅ USB Type-C port — on the keypad, for both display/control firmware flashing and application configuration, from a mobile phone or laptop with no special adapter
✅ EmoSoftCom PC software — connects over a standard RS232 cable to the front control panel; records signals with an oscilloscope-style trend view, and saves or loads complete backup parameter sets — useful for service, maintenance or replicating settings across multiple drives
Commissioning workflow
💡 Typical first-run sequence: power up the drive → enter the motor’s nameplate data → choose V/F control for general use or Field-Oriented Control where more precise speed/torque control is needed → configure the brake chopper settings if your load needs controlled deceleration (built in up to 45kW) → set up load monitoring, timers, counters and virtual I/O logic if your application needs in-built sequencing without external hardware → apply one of the specialized application macros if your setup matches brake control or a multi-pump system → if precise speed feedback is required, fit and configure the appropriate encoder or resolver board (see Accessories) → if motor thermal protection via a sensor is required, fit and configure the PTC/PT100/PT1000 board → back up the finished parameter set via the keypad or EmoSoftCom before handover.
Communication setup
✅ Built-in serial communication over RS232 (for EmoSoftCom/PC connection) and RS485 (for a Modbus fieldbus network) via the X4 terminal block
✅ CG lists EtherNet/IP, Modbus TCP/IP and Profinet as upcoming communication options for this series — not yet available at the time of this catalog
🧩 Accessories & Optional Boards
| Accessory | Description |
|---|---|
| I/O Board — Option 1 | 5 extra relay outputs (250VAC/8A, NO/NC). Max 2 relay boards can be built in per drive |
| I/O Board — Option 2 | 4 extra analog inputs (bipolar −10V to +10V or 0/4–20mA), 2 extra analog outputs (unipolar 0 to +10V or 0/4–20mA), and 4+2 extra digital inputs (24V PNP/NPN logic, programmable, 2 high-speed). Max 1 I/O board per drive |
| Incremental Encoder Board (from frame X2 onward) | Differential input for 5V (TTL) or 24V (HTL) incremental encoders, 5–16384 pulses/revolution, min 9kΩ input, max frequency 100kHz. Single-ended or differential (A/B/Z, A′/B′/Z′). Selectable 5VDC or 24VDC encoder supply |
| Sin-Cos Encoder Board (from frame X2 onward) | Differential input for sin-cos encoders, 1–65535 pulses/revolution, max frequency 350kHz. Differential type (A/B/C/D/Z, A′/B′/C′/D′/Z′). Selectable 5VDC, 12VDC or 24VDC encoder supply |
| Resolver Board (from frame X2 onward) | Differential encoder input, 7Vrms at 20kHz, for differential type resolvers (A/B/Z, A′/B′/Z′) |
| PTC/PT100/PT1000 Board | 1 isolated PTC input per DIN 44081/44082 (up to 6 PTC thermistors in series), plus 3 PT100/PT1000 inputs (2/3/4-wire, per EN 60751). Max 1 board per drive |
| External Braking Resistor | Required above 45kW, where the brake chopper itself is optional rather than built in, via the DC+/PB/DC− terminals |
💡 A maximum of 1 encoder board and 1 I/O board can be fitted per drive (2 relay boards if using I/O Option 1 exclusively), and a maximum of 1 PTC/PT100/PT1000 board per drive.
🏭 Typical Applications
✅ FMCG & packaging — conveyors, packaging lines and general material handling
✅ Port & shipping, infrastructure and cement — heavy-duty motor control in demanding, high-dust or high-vibration environments
✅ Electronics & chemicals — precise, repeatable motor control for process and assembly equipment
✅ Textiles — general-purpose motor control for textile machinery
✅ Renewables & thermal power — auxiliary drives (fans, pumps) in power generation plants
✅ Oil & gas — motor control in harsh, hot or humid field environments, aided by the drive’s 50°C-rated ambient and conformal-coated boards
✅ Automobiles & paper — general manufacturing and process-line motor control
CG notes that AMX series drives can be used across a wide range of general-purpose machine applications, well beyond the industries listed above.
❓ Frequently Asked Questions
What’s the difference between the current AMX48 range and the “Upcoming Range” models?
✅ The eight models from AMX48-004 to AMX48-038 (frames X1–X3, 1.5–18.5kW Normal Duty) are the currently confirmed lineup. The five largest models, AMX48-045 through AMX48-112 (frames X4–X5, 22–55kW Normal Duty), are listed in CG’s own catalog as an “Upcoming Range” — their ratings and dimensions are published, but weight and flow-rate figures aren’t finalized yet.
Does the AMX have a built-in brake chopper?
✅ Yes, up to 45kW it’s built in. Above 45kW, the brake chopper becomes an optional add-on, and an external braking resistor connects via the DC+/PB/DC− terminals.
Does the AMX support fieldbus communication like Profibus or EtherNet/IP?
✅ Today, the AMX ships with RS232 (for PC/EmoSoftCom connection) and RS485 (for Modbus) built in. EtherNet/IP, Modbus TCP/IP and Profinet are listed by CG as upcoming communication options, not yet available.
Do I need an encoder board for the AMX?
✅ Only if your application needs closed-loop vector control with precise speed feedback. Open-loop vector control (1:200 speed range) and V/F control run without any encoder at all; a closed-loop vector setup (1:1500 speed range) needs an incremental, sin-cos or resolver encoder board, available from frame X2 upward.
What ambient temperature can the AMX run in without derating?
✅ Up to 50°C with no derating at all — a genuinely useful margin for hot plant rooms, outdoor enclosures or poorly ventilated panels. Beyond that, output current derates by 1% per °C up to a 55°C maximum.
📦 Availability
The CG Emotron AMX series is not yet listed in our online catalog. The eight confirmed models (AMX48-004 through AMX48-038, 1.5–18.5kW Normal Duty) are expected to be added to the shop shortly; the five largest models (AMX48-045 through AMX48-112) are still an “Upcoming Range” per CG’s own catalog and aren’t in production yet. If you need an AMX drive for your application in the meantime, contact us directly for pricing and lead time.